10 m3 Cylindrical Cryogenic Liquid Storage Tank
10 m3 Cylindrical Cryogenic Liquid Storage Tank: Your Solution for Safe and Efficient Cryogenic Storage
When it comes to storing cryogenic liquids like Liquid Oxygen (LOX), Liquid Nitrogen (LN2), Liquid Argon (LAr), and Liquid Carbon Dioxide (LCO2), safety, reliability, and efficiency are paramount. Our 10 m3 (10,000 Liters) Cylindrical Cryogenic Liquid Storage Tank is engineered to meet and exceed these critical requirements, providing a robust and cost-effective solution for a wide range of industrial and research applications.
Key Features and Benefits
Optimized Capacity: The 10 m3 volume offers a balanced solution, providing substantial storage capacity while remaining manageable for various installation scenarios. This size is ideal for medium-scale consumption in manufacturing, medical, and scientific settings.
Durable Cylindrical Design: The cylindrical design ensures structural integrity and efficient space utilization. The horizontal orientation simplifies access for filling, dispensing, and maintenance.
High-Quality Materials and Construction: Manufactured with premium-grade materials and advanced welding techniques, our cryogenic tanks are built to withstand the extreme temperature differentials associated with cryogenic storage. The inner vessel is typically constructed of stainless steel to ensure compatibility with the stored cryogenic liquids.
Superior Insulation: Our tanks incorporate advanced vacuum insulation technology to minimize heat leak and reduce boil-off losses. This results in significant cost savings over the lifespan of the tank. The vacuum insulation is meticulously applied and tested to maintain its effectiveness.
Robust Safety Features: Safety is our top priority. Each tank is equipped with multiple safety features, including pressure relief valves, burst discs, and level indicators. These features are designed to protect personnel and equipment in the event of overpressure or other abnormal conditions.
Compliance and Certifications: Our cryogenic tanks meet or exceed all relevant industry standards and regulations. We hold national-level A2 pressure vessel manufacture license and D1/D2 pressure vessel design license. Furthermore, we are certified with ISO9001 International Quality System Certificate, GC2/GC3 pressure piping design license, GC2/GC3 pressure piping installation license, and other series of qualifications for supporting engineering design, installation, inspection and maintenance . Our products also carry CCS, CE, and ASME certifications.
Detailed Specifications and Parameters
The following table outlines the specifications of our 10 m3 cylindrical cryogenic liquid storage tank, along with other related models. Customization is available to meet specific client requirements.
| Parameter | CFL10/0.8 | CFL10/1.6 | CFL10/2.16 | Unit | Notes |
|---|---|---|---|---|---|
| Model | CFL10/0.8 | CFL10/1.6 | CFL10/2.16 | Model Number | |
| Working Pressure | 0.8 | 1.6 | 2.16 | MPa | Maximum allowable working pressure |
| Working Medium | LOX/LN2/LAr | LOX/LN2/LAr | LCO2 | Liquid Oxygen (LOX), Liquid Nitrogen (LN2), Liquid Argon (LAr), Liquid Carbon Dioxide (LCO2) | |
| Volume | 10 | 10 | 10 | m3 | Usable volume of the tank |
| Outside Size | φ2100*7170 | φ2000*7930 | φ2100*7130 | mm | Diameter x Length |
| Weight | 5378 | 6787 | 6986 | kg | Empty weight of the tank |
Other Available Models and Specifications:
| Model | Working Pressure (MPa) | Working Medium | Volume (m3) | Outside Size (mm) | Weight (kg) |
|---|---|---|---|---|---|
| CFL5/0.8 | 0.8 | LOX, LN2, LAr | 5 | φ2000*5130 | 3412 |
| CFL20/0.8 | 0.8 | LOX, LN2, LAr | 20 | φ2500*8760 | 8255 |
| CFL30/0.8 | 0.8 | LOX, LN2, LAr | 30 | φ2900*8960 | 12899 |
| CFL50/0.8 | 0.8 | LOX, LN2, LAr | 50 | φ3100*12060 | 18960 |
| CFL100/0.8 | 0.8 | LOX, LN2, LAr | 100 | φ3600*17250 | 34480 |
| CFL5/1.6 | 1.6 | LOX, LN2, LAr | 5 | φ2000*5130 | 3945 |
| CFL20/1.6 | 1.6 | LOX, LN2, LAr | 20 | φ2400*9680 | 10744 |
| CFL30/1.6 | 1.6 | LOX, LN2, LAr | 30 | φ2700*10500 | 14640 |
| CFL50/1.6 | 1.6 | LOX, LN2, LAr | 50 | φ3000*12760 | 23370 |
| CFL5/2.16 | 2.16 | LCO2 | 5 | φ2000*4250 | 4450 |
| CFL20/2.16 | 2.16 | LCO2 | 20 | φ2500*8760 | 11328 |
| CFL30/2.16 | 2.16 | LCO2 | 30 | φ2900*8960 | 17961 |
| CFL50/2.16 | 2.16 | LCO2 | 50 | φ3200*11300 | 26097 |
| CFL100/2.16 | 2.16 | LCO2 | 100 | φ3500*18250 | 49627 |
Note: Custom sizes and pressure ratings are available upon request.
Painting and Surface Protection
Premium Coating System: To ensure long-lasting protection against corrosion and environmental factors, our tanks undergo a rigorous painting process. We use high-performance Acrylic polyurethane or imported coatings that provide exceptional durability and a professional finish.
Multi-Layer Application: The painting process involves a three-layer application: two coats of primer for optimal adhesion and corrosion resistance, followed by one coat of face paint (finish) to provide the desired aesthetic appearance and further protection.
Total Thickness: The total paint thickness exceeds 250 microns, providing a robust barrier against the elements and ensuring a long service life.
Vacuum Performance and Quality Control
Inner Cylinder Preparation: Before vacuum insulation is applied, the inner cylinder undergoes a thorough circulation heating process to eliminate any moisture and ensure optimal vacuum performance.
Stringent Vacuum Testing: We conduct static observation to guarantee the vacuum integrity remains consistent for a minimum of one month, ensuring long-term insulation effectiveness.
Nitrogen Pressure Testing: All products undergo pressure testing using gas nitrogen, which is free of water and oil. This ensures that the equipment remains free from contamination throughout the testing process.
Valve Selection and Options
High-Quality Valves: We utilize Chinese high-quality valves as standard, known for their reliability and performance.
Imported Valve Options: Upon customer request, we can also provide imported valves from reputable international manufacturers to meet specific application requirements and preferences.
Comprehensive Service and Support
We offer a full range of services to support your cryogenic storage needs, including:
Engineering Design and Consulting: Our experienced engineers can assist with the design and optimization of your cryogenic storage system.
Installation and Commissioning: We provide professional installation and commissioning services to ensure proper operation of your tank.
Maintenance and Repair: Our skilled technicians offer comprehensive maintenance and repair services to keep your tank in optimal condition.
Contact us today to discuss your cryogenic liquid storage requirements and learn how our 10 m3 Cylindrical Cryogenic Liquid Storage Tank can benefit your operations.